Directly to content
  1. Publishing |
  2. Search |
  3. Browse |
  4. Recent items rss |
  5. Open Access |
  6. Jur. Issues |
  7. DeutschClear Cookie - decide language by browser settings

Antibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use

Leitgeb, Johannes ; Schuster, Rupert ; Yee, Bit New ; Chee, Pui Fong ; Harnoss, Julian-Camill ; Starzengruber, Peter ; Schäffer, Michael ; Assadian, Ojan

In: BMC surgery, 15 (2015), Nr. 81. pp. 1-5. ISSN 1471-2482

[thumbnail of 12893_2015_Article_58.pdf]
Preview
PDF, English
Download (383kB) | Lizenz: Creative Commons LizenzvertragAntibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use by Leitgeb, Johannes ; Schuster, Rupert ; Yee, Bit New ; Chee, Pui Fong ; Harnoss, Julian-Camill ; Starzengruber, Peter ; Schäffer, Michael ; Assadian, Ojan underlies the terms of Creative Commons Attribution 3.0 Germany

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Background: A surgical glove will protect surgeons and patients only if the glove’s integrity remains intact. However, several studies have demonstrated that undetected micro-perforations of surgical gloves are common. Because of the possibility of surgical glove puncture, an antimicrobial surgical glove was developed. The aim of this laboratory based experimental study was to assess the antibacterial efficacy of the interior chlorhexidine-gluconate (CHG)-coat of an antimicrobial synthetic polyisoprene surgical glove by using a standardized microbiological challenge. Methods: Sixteen healthy adult participants donned one antimicrobial surgical glove and one non-antimicrobial surgical glove randomly allocated to their dominant and non-dominant hand following a crossover design. During a 2-h wear time, participants performed standardized finger and hand movements. Thereafter, the interior surface of excised fingers of the removed gloves was challenged with 8.00 log10 cfu/mL S. aureus (ATCC 6538) or K. pneumoniae (ATCC 4352), respectively. The main outcome measure was the viable mean log10 cfu counts of the two glove groups after 5 min contact with the interior glove’s surface. Results: When comparing an antimicrobial glove against an untreated reference glove after 2-h simulated use wear-time, a mean reduction factor of 6.24 log10 (S. aureus) and 6.22 log10 (K. pneumoniae) was achieved after 5 min contact. Conclusion: These results demonstrate that wearing antibacterial gloves on hands does not negatively impact their antibacterial activity after 2-h of wear. This may have a potential benefit for patient safety in case of glove puncture during surgical procedures.

Document type: Article
Journal or Publication Title: BMC surgery
Volume: 15
Number: 81
Publisher: BioMed Central
Place of Publication: London
Date Deposited: 14 Dec 2015 14:42
Date: 2015
ISSN: 1471-2482
Page Range: pp. 1-5
Faculties / Institutes: Medizinische Fakultät Heidelberg > Chirurgische Universitätsklinik
DDC-classification: 610 Medical sciences Medicine
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative