Directly to content
  1. Publishing |
  2. Search |
  3. Browse |
  4. Recent items rss |
  5. Open Access |
  6. Jur. Issues |
  7. DeutschClear Cookie - decide language by browser settings

Techniques to prevent sample surface charging and reduce beam damage effects for SBEM imaging

Titze, Benjamin

[thumbnail of Dissertation]
Preview
PDF, English (Dissertation)
Download (24MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Sample surface charging and electron beam damage are common problems in scanning electron microscopy. In the case of serial block‐face electron microscopy (SBEM), sample charging prevents or restricts stack acquisition of non-conducting samples in high vacuum; beam damage imposes a lower limit on the cutting thickness (z-resolution). In this dissertation, I present three approaches that aim to overcome these limitations. To solve the charging problem, I implemented and evaluated two charge elimination techniques for SBEM: surface charge neutralization with an ion gun and automated in-chamber specimen coating with an electron beam evaporator. The ion gun method provides only partial charge neutralization in many cases, although high positive ion current densities are achieved. The automated in-chamber coating method, on the other hand, provides reliable charge elimination in all cases and allows the acquisition of SBEM stacks of non-conducting samples in high vacuum. Thin metallic films provide charge elimination for large sample surfaces and high beam currents, and reduce the signal-to-noise ratio less than the widely-used low-vacuum method. To reduce the effects of beam damage – with the aim of allowing thin cutting at higher electron doses – I have explored imaging and cutting at low temperatures (~100 K) using a closed-loop cooling system and a custom-built cryo-microtome. Further experiments will be necessary to quantify potential improvements of 'Cryo-SBEM' over room-temperature SBEM operation.

Document type: Dissertation
Supervisor: Denk, Prof. Dr. Winfried
Date of thesis defense: 24 July 2013
Date Deposited: 07 Aug 2013 05:31
Date: 2013
Faculties / Institutes: Service facilities > Max-Planck-Institute allgemein > MPI for Medical Research
DDC-classification: 530 Physics
600 Technology (Applied sciences)
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative