- LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

Behnes, Michael ; Akin, Ibrahim ; Sartorius, Benjamin ; Fastner, Christian ; El-Battrawy, Ibrahim ; Borggrefe, Martin ; Haubenreisser, Holger ; Meyer, Mathias ; Schönberg, Stefan O. ; Henzler, Thomas

In: BMC Medical Imaging, 16 (2016), Nr. 25. pp. 1-10. ISSN 1471-2342

[thumbnail of 12880_2016_Article_127.pdf]
Preview
PDF, English
Download (2MB) | Lizenz: Creative Commons Lizenzvertrag- LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography by Behnes, Michael ; Akin, Ibrahim ; Sartorius, Benjamin ; Fastner, Christian ; El-Battrawy, Ibrahim ; Borggrefe, Martin ; Haubenreisser, Holger ; Meyer, Mathias ; Schönberg, Stefan O. ; Henzler, Thomas underlies the terms of Creative Commons Attribution 3.0 Germany

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Background: A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. Methods: cCTA datasets were acquired on a 3rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. Results: The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. Conclusions: This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation.

Document type: Article
Journal or Publication Title: BMC Medical Imaging
Volume: 16
Number: 25
Publisher: BioMed Central
Place of Publication: London
Date Deposited: 14 Apr 2016 10:41
Date: 2016
ISSN: 1471-2342
Page Range: pp. 1-10
Faculties / Institutes: Medizinische Fakultät Mannheim > Institut für Klinische Radiologie
Medizinische Fakultät Mannheim > Medizinische Klinik - Lehrstuhl für Innere Medizin I
Service facilities > Zentralinstitut für Seelische Gesundheit
DDC-classification: 610 Medical sciences Medicine
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative