eprintid: 12936 rev_number: 6 eprint_status: archive userid: 1 dir: disk0/00/01/29/36 datestamp: 2012-01-16 14:51:02 lastmod: 2014-04-03 23:17:38 status_changed: 2012-08-15 09:03:53 type: doctoralThesis metadata_visibility: show creators_name: Welte, Joachim title: Atom Trap Trace Analysis of Ar-39 title_de: Atomfallen-Spurenstoffanalyse von Ar-39 ispublished: pub subjects: ddc-530 divisions: i-130700 adv_faculty: af-13 keywords: magneto-optical trap , single atom , argon-39 , fluorescence detection , laser cooling cterms_swd: Magnetooptische Atomfalle cterms_swd: Spurenstoff cterms_swd: Argon cterms_swd: Argon-39 cterms_swd: Atomoptik cterms_swd: Fluoreszenz cterms_swd: Laserinduzierte Fluoreszenz cterms_swd: Laserkühlung abstract: Entwurf und Umsetzung eines Systems zum Einzelatomnachweis von Argon-39 Der Nachweis von 39Ar in natürlichen Wasserproben kann zur radiometrischen Altersbestimmung auf Zeitskalen von 50 bis 1000 Jahren vor heute verwendet werden. Diese experimentelle Forschungsarbeit stellt den Aufbau einer Atomstrahl- und Fallenapparatur vor, welche 39Ar-Atome mittels der laserkühlungsbasierten Methode “Atom Trap Trace Analysis” einfängt und nachweist. Auf diese Art könnten die bestehenden Beschränkungen des indirekten Nachweises über Zerfallsprodukte (“low-level counting”) bezüglich Probengröße und Messdauer aufgehoben werden. Im Rahmen dieser Arbeit wurde das Hyperfeinstrukturspektrum des Kühlübergangs 1s5-2p9 experimentell bestimmt. Desweiteren wurde ein optisch kollimierter, hochintensiver Strahl kalter metatabiler Argonatome erzeugt und der Nachweis einzelner 39Ar-Atome über Fluoreszenzmessung realisiert. Bislang wurden 39Ar-Zählraten von 1 Atom in ungefähr 4 Stunden für atmosphärisches Argon erreicht. Neueste Verbesserungen deuten außerdem darauf hin, dass Zählraten von 1 Atom/h möglich sind. abstract_translated_text: Design and realization of a detection system for single argon-39 atoms Detection of 39Ar in natural water samples can be employed for radiometric dating on a timescale of 50 to 1000 years before present. This experimental work comprises the setup of an atomic beam and trap apparatus that captures and detects 39Ar atoms by the laser-cooling technique “Atom Trap Trace Analysis”. With this approach, the limitations of low-level counting, regarding sample size and measurement time, could be overcome. In the course of this work, the hyperfine structure spectrum of the cooling transition 1s5-2p9 has been experimentally determined. A high intensity, optically collimated beam of slow metastable argon atoms has been set up and fluorescence detection of individual 39Ar atoms in a magneto-optical trap is realized. 39Ar count rates of 1 atom in about 4 hours have been achieved for atmospheric argon. Recent improvements further suggest that even higher count rates of 1 atom/hour are within reach. abstract_translated_lang: eng date: 2011 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00012936 ppn_swb: 1651257620 own_urn: urn:nbn:de:bsz:16-opus-129366 date_accepted: 2011-12-14 advisor: HASH(0x561a629666b0) language: eng bibsort: WELTEJOACHATOMTRAPTR2011 full_text_status: public citation: Welte, Joachim (2011) Atom Trap Trace Analysis of Ar-39. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/12936/1/thesis_welte_joachim.pdf