eprintid: 13600 rev_number: 14 eprint_status: archive userid: 1 dir: disk0/00/01/36/00 datestamp: 2012-07-31 10:52:05 lastmod: 2024-06-12 11:29:36 status_changed: 2012-07-31 10:52:05 type: article metadata_visibility: show creators_name: Karch, Dominik creators_name: Kim, Keun-Sun creators_name: Wochner, Katarzyna creators_name: Philippi, Heike creators_name: Pietz, Joachim creators_name: Dickhaus, Hartmut title: Compensation of large motion sensor displacements during long recordings of limb movements ispublished: pub subjects: ddc-000 divisions: i-911810 keywords: Sensor displacement , Electromagnetic tracking , Infant movement analysis cterms_swd: Bewegungsanalyse abstract: In motion capture applications using electromagnetic tracking systems the process of anatomical calibration as- sociates the technical frames of sensors attached to the skin with the human anatomy. Joint centers and axes are determined relative to these frames. A change of orientation of the sensor relative to the skin renders this calibration faulty. This sensitivity regarding sensor displacement can turn out to be a serious problem with movement recordings of several minutes duration. We propose the “dislocation distance” as a novel method to quantify sensor displacement and to detect gradual and sudden changes of sensor orientation. Furthermore a method to define a so called fixed technical frame is proposed as a robust reference frame which can adapt to a new sensor orientation on the skin. The proposed methods are applied to quantify the effects of sensor displacement of 120 upper and lower limb movement recordings of newborns revealing the need for a method to compensate for sensor displacement. The reliability of the fixed technical frame is quantified and it is shown that trend and dispersion of the dislocation distance can be signif- icantly reduced. A working example illustrates the consequences of sensor displacement on derived angle time series and how they are avoided using the fixed technical frame. abstract_translated_lang: eng date: 2010 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00013600 ppn_swb: 1651640661 own_urn: urn:nbn:de:bsz:16-opus-136007 language: eng bibsort: KARCHDOMINCOMPENSATI2010 full_text_status: public publication: ournal of Biomechanics citation: Karch, Dominik ; Kim, Keun-Sun ; Wochner, Katarzyna ; Philippi, Heike ; Pietz, Joachim ; Dickhaus, Hartmut (2010) Compensation of large motion sensor displacements during long recordings of limb movements. ournal of Biomechanics . document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/13600/1/compensation_of_large_sensor_displacements.pdf