eprintid: 1783 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/17/83 datestamp: 2001-10-01 00:00:00 lastmod: 2014-04-03 11:17:43 status_changed: 2012-08-14 15:02:37 type: doctoralThesis metadata_visibility: show creators_name: Müller, Claus title: Oberflächenwellen Sensorik für Schadstoff-Messungen: NOx-Nachweis bis in den sub-ppb Bereich mit einer zyklischen Meßmethode title_en: surface acoustic wave sensoric for pollution measurements: NOx detection into the sub ppb region with a cyclic technique ispublished: pub subjects: 530 divisions: 130700 adv_faculty: af-13 keywords: Oberflächenwellen , Sensorik , SchadstoffmessungSurface acoustic wave , gas sensor , nitrogen dioxide , nitrogen monoxide , phthalocyanine cterms_swd: Phthalocyanin cterms_swd: Gassensor cterms_swd: Stickstoffmonoxid cterms_swd: Stickstoffdioxid abstract: Der Nachweis des Schadstoffes NO2 in der Außenluft erfordert Sensoren, die Konzentrationen bis in den untersten ppb Bereich nachweisen können. Für diese Aufgabe werden üblicherweise teure Systeme eingesetzt, die auf dem Prinzip der Chemilumineszenz beruhen. In dieser Arbeit wird ein kostengünstiger Oberflächenwellensensor vorgestellt, bei dem als Sensorsignal die zeitliche Änderung der Dämpfung der Oberflächenwelle ausgewertet wird. Eine zyklische Methode bringt den Sensor nach jeder Messung wieder in einen fast vollständig NO2-freien Zustand. Mit dieser Technik wird eine Empfindlichkeit von besser als 1 ppb im Konzentrationsbereich von 0,8 bis 150 ppb erreicht. Das Signal ist sehr stabil. abstract_translated_text: The detection of NO2 in ambient air requires sensors that are capable of measuring concentrations in the low ppb range. Usually expensive systems based on gas phase chemoluminescence are used. We present a cheap surface acoustic wave (SAW) Sensor with the capability to detect NO2 in the 1 ppb concentration region. As the sensor signal we use the temporal attenuation change of the SAW sensor. A cyclic technique returns the sensor into a nearly NO2 free initial state. With this technique we reach a resolution of less than 0,8 ppb in the 1 to 150 ppb concentration range. The signal is extreme stable. abstract_translated_lang: eng class_scheme: pacs class_labels: 77.65.Dq date: 2001 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00001783 ppn_swb: 1643238825 own_urn: urn:nbn:de:bsz:16-opus-17835 date_accepted: 2001-07-19 advisor: HASH(0x5561209149d8) language: ger bibsort: MULLERCLAUOBERFLACHE2001 full_text_status: public citation: Müller, Claus (2001) Oberflächenwellen Sensorik für Schadstoff-Messungen: NOx-Nachweis bis in den sub-ppb Bereich mit einer zyklischen Meßmethode. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/1783/1/allesv.pdf