eprintid: 22187 rev_number: 13 eprint_status: archive userid: 1589 dir: disk0/00/02/21/87 datestamp: 2016-11-22 13:43:22 lastmod: 2024-04-27 18:44:24 status_changed: 2016-11-22 13:43:22 type: article metadata_visibility: show creators_name: Weingärtner, Sebastian creators_name: Meßner, Nadja M. creators_name: Budjan, Johannes creators_name: Loßnitzer, Dirk creators_name: Mattler, Uwe creators_name: Papavassiliu, Theano creators_name: Zöllner, Frank G. creators_name: Schad, Lothar R. title: Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI subjects: 610 divisions: 61800 divisions: 62200 divisions: 63600 abstract: Background: Myocardial T1-mapping recently emerged as a promising quantitative method for non-invasive tissue characterization in numerous cardiomyopathies. Commonly performed with an inversion-recovery (IR) magnetization preparation at 1.5T, the application at 3T has gained due to increased quantification precision. Alternatively, saturation-recovery (SR) T1-mapping has recently been introduced at 1.5T for improved accuracy. Thus, the purpose of this study is to investigate the robustness and precision of SR T1-mapping at 3T and to establish accurate reference values for native T1-times and extracellular volume fraction (ECV) of healthy myocardium. Methods: Balanced Steady-State Free-Precession (bSSFP) Saturation-Pulse Prepared Heart-rate independent Inversion-REcovery (SAPPHIRE) and Saturation-recovery Single-SHot Acquisition (SASHA) T1-mapping were compared with the Modified Look-Locker inversion recovery (MOLLI) sequence at 3T. Accuracy and precision were studied in phantom. Native and post-contrast T1-times and regional ECV were determined in 20 healthy subjects (10 men, 27 ± 5 years). Subjective image quality, susceptibility artifact rating, in-vivo precision and reproducibility were analyzed. Results: SR T1-mapping showed <4 % deviation from the spin-echo reference in phantom in the range of T1 = 100–2300 ms. The average quality and artifact scores of the T1-mapping methods were: MOLLI:3.4/3.6, SAPPHIRE:3.1/3.4, SASHA:2.9/3.2; (1: poor - 4: excellent/1: strong - 4: none). SAPPHIRE and SASHA yielded significantly higher T1-times (SAPPHIRE: 1578 ± 42 ms, SASHA: 1523 ± 46 ms), in-vivo T1-time variation (SAPPHIRE: 60.1 ± 8.7 ms, SASHA: 70.0 ± 9.3 ms) and lower ECV-values (SAPPHIRE: 0.20 ± 0.02, SASHA: 0.21 ± 0.03) compared with MOLLI (T1: 1181 ± 47 ms, ECV: 0.26 ± 0.03, Precision: 53.7 ± 8.1 ms). No significant difference was found in the inter-subject variability of T1-times or ECV-values (T1: p = 0.90, ECV: p = 0.78), the observer agreement (inter: p > 0.19; intra: p > 0.09) or consistency (inter: p > 0.07; intra: p > 0.17) between the three methods. Conclusions: Saturation-recovery T1-mapping at 3T yields higher accuracy, comparable inter-subject, inter- and intra-observer variability and less than 30 % precision-loss compared to MOLLI. date: 2016 publisher: BioMed Central id_scheme: DOI ppn_swb: 1654395692 own_urn: urn:nbn:de:bsz:16-heidok-221873 language: eng bibsort: WEINGARTNEMYOCARDIAL2016 full_text_status: public publication: Journal of Cardiovascular Magnetic Resonance volume: 18 number: 84 place_of_pub: London pagerange: 1-9 issn: 1532-429X citation: Weingärtner, Sebastian ; Meßner, Nadja M. ; Budjan, Johannes ; Loßnitzer, Dirk ; Mattler, Uwe ; Papavassiliu, Theano ; Zöllner, Frank G. ; Schad, Lothar R. (2016) Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI. Journal of Cardiovascular Magnetic Resonance, 18 (84). pp. 1-9. ISSN 1532-429X document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/22187/1/12968_2016_Article_302.pdf