eprintid: 3504 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/35/04 datestamp: 2003-06-04 13:53:10 lastmod: 2014-04-03 12:56:59 status_changed: 2012-08-14 15:08:10 type: doctoralThesis metadata_visibility: show creators_name: Hofmann, Rüdiger title: Ein System zur Online-Qualitätssicherung in der Strahlentherapie title_en: A system for online quality assurance in radiation therapy ispublished: pub subjects: 530 divisions: 850300 adv_faculty: af-13 keywords: segmentierter Detektor , Vielkanal-Elektrometer , IMRTsegmentated detector , multi-channel electrometer , IMRT cterms_swd: Qualitätssicherung cterms_swd: Qualitätssicherungssystem cterms_swd: Strahlentherapie cterms_swd: Ionisationskammer abstract: In dieser Arbeit wird ein neuartiges System zur Kontrolle der Lamellenpositionen in einem Multi-Leaf-Kollimator (ModuLeaf MLC, MRC Systems, Heidelberg) für die intensitätsmodulierte Strahlentherapie (IMRT) vorgestellt. Eine in 400 Kanäle segmentierte flüssigkeitsgefüllte Ionisationskammer erreicht eine Ortsauflösung besser als 1 mm, bezogen auf das Isozentrum, in der Bewegungsrichtung der Lamellen, mit der die Form der Kollimatoröffnung in Echtzeít kontrolliert werden kann. Die Ionisationskammer wurde in Zusammenarbeit mit dem Forschungszentrum Karlsruhe (FZK) entwickelt und gebaut. Weitere Untersuchungen wurden angestellt, um eine geeignete Flüssigkeit als sensitives Medium der Ionisationskammer zu finden. Eine geeignete Elektronik, mit der die Kammersignale (wenige nA) gemessen werden können und eine passende Datenauslese wurden zusammengestellt. Das Potential des Systems zur Verbesserung der Qualitätssicherung in der IMRT wird diskutiert. abstract_translated_text: This thesis introduces a new technique to verify the leaf position of multi leaf collimators (ModuLeaf MLC, MRC Systems, Heidelberg) for intensity modulated radiation therapy (IMRT) during beam delivery. The system is based on a liquid filled ionisation chamber which is segmentated into 400 channels. The device is able to resolve a spatial resolution better than 1 mm (at isocentre, in the direction of the leaf travel). It is possible to check the leaf position in realtime using this system. The chamber was constructed and built in cooperation with the research center in Karlsruhe (FZK). Further investigations aim to find a liquid as a sensitive medium for the ionisation chamber. A suitable set of electronics to measure the signals of the chamber (currents of a few nA) and to read out the data was arranged. The potential for improvement of the quality assurance in IMRT of the new device is discussed. abstract_translated_lang: eng class_scheme: pacs class_labels: 87.52.-g R, control, and safety date: 2003 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00003504 ppn_swb: 1643464035 own_urn: urn:nbn:de:bsz:16-opus-35042 date_accepted: 2003-05-28 advisor: HASH(0x556120d61a60) language: ger bibsort: HOFMANNRUDEINSYSTEMZ2003 full_text_status: public citation: Hofmann, Rüdiger (2003) Ein System zur Online-Qualitätssicherung in der Strahlentherapie. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/3504/1/RHofmann.pdf