eprintid: 3589 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/35/89 datestamp: 2003-07-08 11:30:09 lastmod: 2014-04-03 13:00:41 status_changed: 2012-08-14 15:08:27 type: doctoralThesis metadata_visibility: show creators_name: Gröning, Hermann title: Radiometrische Kalibrierung und Charakterisierung von CCD- und CMOS Bild-Sensoren und Monokulares 3D-Tracking in Echtzeit ispublished: pub subjects: ddc-530 divisions: i-708000 adv_faculty: af-13 keywords: Monokular 3D-Tracking , Echtzeit , spektrale Strahlungsdichte , Ullbrichtkugel , Rauschen , Quanteneffizienz , Fix-Muster-Rauschen , HDRC-VideosensorMonocular 3D-Tracking , Real Time , HDRC Quantum-Efficiency , spectral-Radiance , Fix-Pattern-Noise cterms_swd: Kalibrieren cterms_swd: CCD-Sensor cterms_swd: CCD-Videokamera cterms_swd: CMOS abstract: In der vorliegenden Arbeit werden sowohl eine CCD-Kamera, als auch eine CMOS-Kamera auf ihre grundlegenden Eigenschaften hin überprüft. Ausserdem wird mit der CMOS-Kamera ein neuartiges monokulares 3D-Tracking in Echtzeit durchgeführt. Bei beiden Sensoren wird der Dunkelstrom untersucht. Bei der CCD-Kamera werden die Linearität und die Globale Totale Rauschvarianz bestimmt und das Fix-Muster Rauschen korrigiert. Die absolute Quanteneffizienz wird aus der kalibrierten spektralen Strahlungsdichte der homogenen Lichtquelle berechnet. Ausserdem wird das Signal-Rauschverhältnis und der relative Fehler bestimmt. Bei der CMOS-Kamera wird die Antwort-Kurve modelliert und bei vorgebener Quanteneffizienz aus der kalibrierten spekralen Strahlungdichte der homogenen Lichtquelle berechnet. Ausserdem wird die Globale Totale Rauschvarianz gemessen und daraus das Signal-Rauschverhältnis und der relative Fehler berechnet. abstract_translated_text: In this presented thesis a CCD and a CMOS image sensor are characterized relative to their fundamental radiometric properties. A new technic for a monocular 3D-Tracking is realized. Dark currents of both sensors are examined. The linearity and the global total variance of noise of the CCD image sensor are determined and the fixed-pattern noise is corrected. The absolute quantum efficiency is calculated from calibrated data of the spectral radiance of the integration sphere. Additionally the signal noise ratio and the relative error are determined. The response of the CMOS sensor is modeled and can be computed from the calibrated data of the spectral radiance with known data of the quantum efficiency. The global total variance of noise is measured. The signal noise ratio and the relative error are computed with these data. abstract_translated_lang: eng class_scheme: pacs class_labels: 85.60.-q O date: 2003 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00003589 ppn_swb: 1643466062 own_urn: urn:nbn:de:bsz:16-opus-35897 date_accepted: 2003-02-12 advisor: HASH(0x558eaa7ee5d8) language: ger bibsort: GRONINGHERRADIOMETRI2003 full_text_status: public citation: Gröning, Hermann (2003) Radiometrische Kalibrierung und Charakterisierung von CCD- und CMOS Bild-Sensoren und Monokulares 3D-Tracking in Echtzeit. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/3589/1/phd_hg.pdf