eprintid: 4579 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/45/79 datestamp: 2004-06-18 12:31:06 lastmod: 2014-04-03 13:53:11 status_changed: 2012-08-14 15:12:12 type: doctoralThesis metadata_visibility: show creators_name: Fischer, Stefan Karl title: Entwicklung eines konfokalen Laserscanning-Mikroskops zum Einsatz in der stereotaktischen Laser-Neurochirurgie title_en: Development of a Confocal Laser Scanning Microscope for use in Stereotactic Laser Neuro Surgery ispublished: pub subjects: ddc-530 divisions: i-130700 adv_faculty: af-13 keywords: Laserscanning-MikroskopLaser scanning microscope cterms_swd: Laser-Rastermikroskop cterms_swd: Laserablation cterms_swd: Neurochirurgie cterms_swd: Stereotaxie cterms_swd: Konfokale Mikroskopie cterms_swd: Pikosekundenbereich cterms_swd: Neodym cterms_swd: Lithiumyttriumfluorid abstract: In der vorliegenden Arbeit wurde ein konfokales Laserscanning-Mikroskop entwickelt, das der Überwachung einer stereotakischen Operation mit einer Lasersonde dient. Es werden die Konstruktionsvorgaben und die Folgerungen für das Design des Mikroskops diskutiert und der realisierte Aufbau vorgestellt. Speziell entwickelt wurde sowohl die Optik, als auch die Elektronik und Mechanik des Mikroskops. Die zur Steuerung des Mikroskops programmierte Software hat neben der Bildaufnahme und -darstellung auch die Aufgabe, die Bewegungen der gesamten Sonde zu steuern und mit dem Mikroskop zu koordinieren. Messungen an Testobjekten zeigen die Funktion des Bildaufbaus während der Sondenbewegungen, und in ersten Tierexperimenten wurde gezeigt, daß die Auflösung des Mikroskops ausreicht, Blutgefäße mit relevanten Dimensionen darzustellen. Allerdings zeigte sich, daß der Blutgefäßkontrast noch zu gering ist, um einfach und sicher Gefäße auch eingebettet in Hirngewebe zu erkennen. Hierzu müssen kontraststeigernde Verfahren wie Mehrfarben-Differenzbilder oder Fluoreszenzfarbstoffe eingesetzt werden. Neben der Erprobung des Mikroskops wurde im Tierexperiment auch der Einfluß der Sondenbewegungen und der Spülung getestet. abstract_translated_text: The present work describes the development of a confocal laser scanning microscope for observation of stereotactic interventions using a laser probe. Constructional requirements and conclusions of the microscope design were discussed and the realized setup was shown. Optics, electronics as well as mechanics of the microscope were specially developed. The software controlling the microscope was not only responsible for the data acquisition and visualisation, but also has to control the movement of the laser probe and to synchronise it with the microscope. Measurements of test objects shows the microscope function during probe movements. First animal trials shows the microscope resolution is sufficient to visualise blood vessels of relevant dimensions. But it shows also, blood vessel contrast is not sufficient for easy and reliable identification of blood vessels embedded in brain tissue. Therefore the use of multicolour differential imaging or fluorescence staining is needed to enhance. In addition to the microscope the influence of probe movements and rinsing was tested in animal trials as well. abstract_translated_lang: eng class_scheme: pacs class_labels: 87.62.+n date: 1996 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00004579 ppn_swb: 1643755803 own_urn: urn:nbn:de:bsz:16-opus-45795 date_accepted: 1996-11-07 advisor: HASH(0x55e0f8071e38) language: ger bibsort: FISCHERSTEENTWICKLUN1996 full_text_status: public citation: Fischer, Stefan Karl (1996) Entwicklung eines konfokalen Laserscanning-Mikroskops zum Einsatz in der stereotaktischen Laser-Neurochirurgie. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/4579/1/arb.pdf