eprintid: 5219 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/52/19 datestamp: 2005-01-11 10:55:44 lastmod: 2014-04-03 18:44:21 status_changed: 2012-08-14 15:13:58 type: doctoralThesis metadata_visibility: show creators_name: Kroll, Alexander title: Quantifizierung der Perfusion mit Arterial Spin-Labeling Techniken in der Magnetresonanz-Tomographie an Hand eines Perfusionsphantoms title_en: Perfusion quantitation using a perfusion phantom by means of arterial spin-labeling techniques in MR- tomography ispublished: pub subjects: ddc-530 divisions: i-850300 adv_faculty: af-13 keywords: Arterial Spin LabelingArterial Spin Labeling cterms_swd: Perfusion cterms_swd: Phantom cterms_swd: NMR-Tomographie abstract: Die Arterial Spin-Labeling Technik ermöglicht eine nicht-invasive Perfusionsbestimmung ohne Kontrastmittelgabe mittels Magnetresonanz-Tomographie. Im Rahmen dieser Arbeit wurde erstmalig ein MR-kompatibles künstliches Perfusionsphantom entwickelt und erprobt, mit dem ein Perfusions-Goldstandard in einem Bereich von PhWF = 0,21 ml/s/ml bis 0,56 ml/s/ml mit einer Genauigkeit von deltaPhWF < 5% bestimmt werden kann. An Hand dessen wurde die Quantifizierungsgenauigkeit von drei Techniken zur absoluten Perfusionsbestimmung, die auf Arterial Spin-Labeling und dem Allgemeinen Kinetischen Modell basieren, bestimmt: die Parameterbestimmung mittels nichtlinearer Kurvenanpassung und die QUIPSS I- bzw. QUIPSS II-Techniken. Hierbei zeigte die QUIPSS I-Technik die geringste mittlere Abweichung der Perfusion vom Goldstandard mit f,rel = 6,3% bei einer Korrelation der Messwerte von r = 0,97. Die bereits in Studien verwendete QUIPSS II-Technik weist die höchste Abweichung von f,rel = 13,5% mit der geringsten Korrelation von r = 0,63 auf. Die Ergebnisse der aufwändigeren nichtlinearen Kurvenanpassung besitzen eine Abweichung vom Goldstandard von f,rel = 9,4% mit der höchsten Korrelation von r = 0,98. Auf Grund von technischen Limitationen etablierter Auslesetechniken wurde eine Arterial Spin-Labeling Sequenz mit trueFISP-Auslese entwickelt und auf einem klinischen MR-Tomographen implementiert. Diese modifizierte Sequenz zeigte bei Probandenmessungen am Gehirn deutlich geringere Verzeichnungen im Vergleich zu einer Echo-Planar Technik und kann somit in Zukunft eine präzise biologische Therapieplanung gewährleisten. abstract_translated_text: Arterial spin-labeling is a method to quantify perfusion with MR-tomography non-invasively without the need for contrast agents. In this work an MR-compatible artificial perfusion phantom was developed and tested for the first time, defining a gold-standard for perfusion in the range of PhWF = 0.21 ml/s/ml to 0.56 ml/s/ml with an accuracy of deltaPhWF < 5%. Using this gold-standard, the accuracy of three techniques for perfusion quantitation based on arterial spin-labeling and the general kinetic model were determined: non-linear curve fitting and QUIPSS I- respectively QUIPSS II-techniques. The QUIPSS I-technique showed the smallest deviation from the gold-standard with f,rel = 6.3% and a correlation of r = 0.97. The QUIPSS II-technique, already used in clinical studies, had the highest deviation of f,rel = 13.5% with the lowest correlation of r = 0.63. Using the complex non-linear curve fitting, the results showed a deviation from the gold-standard of f,rel = 9.4 % but with the best correlation (r = 0.98). Due to the technical limitations of established imaging techniques, an arterial spin-labeling sequence using the trueFISP imaging technique had to be developed and implemented on a clinical MR-system. This new sequence showed less distortions in the brain compared to an EPI-sequence in volunteer experiments. In future, this sequence might yield a higher accuracy in biology-based therapy planning. abstract_translated_lang: eng date: 2004 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00005219 ppn_swb: 54751753X own_urn: urn:nbn:de:bsz:16-opus-52190 date_accepted: 2004-12-22 advisor: HASH(0x55de57a60030) language: ger bibsort: KROLLALEXAQUANTIFIZI2004 full_text_status: public citation: Kroll, Alexander (2004) Quantifizierung der Perfusion mit Arterial Spin-Labeling Techniken in der Magnetresonanz-Tomographie an Hand eines Perfusionsphantoms. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/5219/1/Dissertation_Kroll.pdf