eprintid: 5501 rev_number: 8 eprint_status: archive userid: 1 dir: disk0/00/00/55/01 datestamp: 2005-05-04 09:19:45 lastmod: 2014-04-03 18:57:18 status_changed: 2012-08-14 15:14:57 type: doctoralThesis metadata_visibility: show creators_name: Rashev, Mikhail title: A new Time-of-flight Spectrometer for Impact Generated Ions title_en: A new Time-of-flight Spectrometer for Impact Generated Ions ispublished: pub subjects: ddc-530 divisions: i-851340 adv_faculty: af-13 keywords: Cosmic dust cterms_swd: Kosmischer Staub abstract: Die vorliegende Arbeit behandelt die Entwicklung eines Flugzeitmassenspektrometers (Large Area Mass Analyzer, LAMA) zur chemischen Analyse von Staubteilchen im Weltraum. Dieses Instrument der naechsten Generation wird eine gro\ss e Detektorflaeche 0.1m^2 haben, um moeglichst viele Staubteilcheneinschlaege zu erhalten. Die Massenaufloesung von m/dm 100 erlaubt es, die haeufigsten in einem Staubteilchen enthaltenen Elemente zu identifizieren. Um den Einschlagsvorgang eines Hochgeschwindigkeitsteilchens zu untersuchen und um neu entwickelte Komponenten des Massenanalysators zu testen, wurde ein Labormodell entwickelt. Es verfuegt ueber ein Reflektron zur Kompensation der Anfangsenergie der Ionen. Eine Mikrokanalplatte dient als Ionendetektor. Der Large Area Mass Analyzer wurde simuliert. Die empfindliche Flaeche des Instruments betraegt ca. 0.1m^2. Die Massenaufloesung liegt im Bereich von 150 - 200. Verbesserungen in der Konstruktion erm\"oglichen den Einbau eines Trajektoriensensors zur Bestimmung von Geschwindigkeit und Masse der Teilchen. Zur geometrischen Konfiguration des Instruments wurden sowohl numerische Simulationen als auch analytische Berechnungen durchgefuehrt. Die Mikrokanalplatte und der neu entwickelte Ion-Elektron-Konverter bilden den Ionendetektor des LAMA. abstract_translated_text: This thesis deals with the development of a time-of-flight mass spectrometer (Large Area Dust Mass Analyzer). This next generation instrument will have a large sensitive area (0.1m^2) in order to achieve a higher number of dust impacts and a mass resolution m/dm > 100 which allows the identification of the most abundant elements in a dust particle. In order to study the hypervelocity impact process as well as to apply new components for mass analyzer the laboratory set-up was built. It has a reflectron in order to compensate initial ion energies and a microchanel plate detector as an ion detector. A laboratory set-up of a high resolution mass analyzer is the first step to a Large Area Mass Analyzer and it was simulated using the $SIMION 7.0 software. This instrument allows to analyze the initial conditions of plasma ions upon a hypervelocity dust particle impact. First mass spectra show the mass resolution close to simulated ones. The Large Area Mass Analyzer has been simulated. The sensitive area of the instrument is about 0.1m^2. The mass resolution varies in the range 150-200. The design improvements allow us to incorporate the trajectory sensor in order to determine the velocity and mass of the dust particles. A simulating software as well as analytical calculations were applied in order to obtain the geometrical configuration. Both a microchannel plate detector and an ion-to-electron converter were designed for the ion detector. abstract_translated_lang: eng date: 2005 date_type: published id_scheme: DOI id_number: 10.11588/heidok.00005501 ppn_swb: 1644026007 own_urn: urn:nbn:de:bsz:16-opus-55018 date_accepted: 2005-02-16 advisor: HASH(0x55e0f7e45478) language: eng bibsort: RASHEVMIKHANEWTIMEOF2005 full_text_status: public citation: Rashev, Mikhail (2005) A new Time-of-flight Spectrometer for Impact Generated Ions. [Dissertation] document_url: https://archiv.ub.uni-heidelberg.de/volltextserver/5501/1/Thesis_Rashev.pdf