Direkt zum Inhalt
  1. Publizieren |
  2. Suche |
  3. Browsen |
  4. Neuzugänge rss |
  5. Open Access |
  6. Rechtsfragen |
  7. EnglishCookie löschen - von nun an wird die Spracheinstellung Ihres Browsers verwendet.

Computer-based comparison of different methods for selecting mitral annuloplasty ring size

Al-Maisary, Sameer ; Engelhardt, Sandy ; Graser, Bastian ; Wolf, Ivo ; Karck, Matthias ; De Simone, Raffaele

In: Journal of Cardiothoracic Surgery, 12 (2017), Nr. 8. S. 1-7. ISSN 1749-8090

[thumbnail of 13019_2017_Article_571.pdf]
Vorschau
PDF, Englisch
Download (883kB) | Lizenz: Creative Commons LizenzvertragComputer-based comparison of different methods for selecting mitral annuloplasty ring size von Al-Maisary, Sameer ; Engelhardt, Sandy ; Graser, Bastian ; Wolf, Ivo ; Karck, Matthias ; De Simone, Raffaele steht unter einer Creative Commons Namensnennung 3.0 Deutschland

Zitieren von Dokumenten: Bitte verwenden Sie für Zitate nicht die URL in der Adresszeile Ihres Webbrowsers, sondern entweder die angegebene DOI, URN oder die persistente URL, deren langfristige Verfügbarkeit wir garantieren. [mehr ...]

Abstract

Background: Ring sizing for mitral valve annuloplasty is conventionally done intraoperatively using specific ‘sizer’ instruments, which are placed onto the valve tissue. This approach is barely reproducible since different sizing strategies have been established among surgeons. The goal of this study is to virtually apply different sizing methods on the basis of pre-repair echocardiography to find out basic differences between sizing strategies. Methods: In three-dimensional echocardiographs of 43 patients, the mitral annulus and the contour of the anterior mitral leaflet were segmented using MITK Mitralyzer software. Similarly, three-dimensional virtual models of Carpentier-Edwards Physio II annuloplasty rings and their corresponding sizers were interactively generated from computer tomography images. For each patient, the matching annuloplasty ring was selected repeatedly according to popular sizing strategies, such as the height of anterior mitral leaflet, the intercommissural distance and the surface area of anterior mitral leaflet. The areas of the selected rings were considered as the neo-surface area of the mitral annulus after implantation. Results: The sizing of the mitral valve according to the height of anterior mitral leaflet (mean ring size = 29.9 ± 3.90), intercommissural distance (mean ring size = 37.5 ± 1.92) or surface area of anterior mitral leaflet (mean ring size = 32.7 ± 3.3) led to significantly different measurements (p ≤ 0.01). In contrary to intercommissural distance, height and surface area of the anterior mitral leaflet exhibited significant variations between the patients (p ≤ 0.01). The sizing according to the height of anterior mitral leaflet led to the maximal reduction of the mitral annulus surface area followed by the sizing according to the surface area of anterior mitral leaflet and finally by the intercommissural distance. Conclusions: This novel comprehensive computer-based analysis reveals that the surveyed sizing methods led to the selection of significantly different annuloplasty rings and therefore underscore the ambiguity of routinely applied annuloplasty sizing strategies.

Dokumententyp: Artikel
Titel der Zeitschrift: Journal of Cardiothoracic Surgery
Band: 12
Nummer: 8
Verlag: BioMed Central
Ort der Veröffentlichung: London
Erstellungsdatum: 09 Feb. 2017 07:58
Erscheinungsjahr: 2017
ISSN: 1749-8090
Seitenbereich: S. 1-7
Institute/Einrichtungen: Zentrale und Sonstige Einrichtungen > Deutsches Krebsforschungszentrum
Medizinische Fakultät Heidelberg und Uniklinikum > Chirurgische Universitätsklinik
DDC-Sachgruppe: 610 Medizin
Leitlinien | Häufige Fragen | Kontakt | Impressum |
OA-LogoDINI-Zertifikat 2013Logo der Open-Archives-Initiative