Directly to content
  1. Publishing |
  2. Search |
  3. Browse |
  4. Recent items rss |
  5. Open Access |
  6. Jur. Issues |
  7. DeutschClear Cookie - decide language by browser settings

Dosimetric comparison of different radiation techniques (IMRT vs. 3-dimensional) of the “true” (deep) ano-inguinal lymphatic drainage of anal cancer patients

Dapper, Hendrik ; Oechsner, Markus ; Hirche, Christoph ; Münch, Stefan ; Sauter, Christina ; Borm, Kai ; Peeken, Jan C. ; Combs, Stephanie E. ; Habermehl, Daniel

In: Radiation Oncology, 13 (2018), Nr. 227. pp. 1-7. ISSN 1748-717X

[thumbnail of 13014_2018_Article_1174.pdf] PDF, English
Download (1MB) | Lizenz: Creative Commons LizenzvertragDosimetric comparison of different radiation techniques (IMRT vs. 3-dimensional) of the “true” (deep) ano-inguinal lymphatic drainage of anal cancer patients by Dapper, Hendrik ; Oechsner, Markus ; Hirche, Christoph ; Münch, Stefan ; Sauter, Christina ; Borm, Kai ; Peeken, Jan C. ; Combs, Stephanie E. ; Habermehl, Daniel underlies the terms of Creative Commons Attribution 4.0

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Introduction: The ano-inguinal lymphatic drainage (AILD) is located in the subcutaneous adipose tissue of the proximal medial thigh. Currently, there are no recommendations for an inclusion of the ‘true’ AILD in the clinical target volume (CTV) of definitive chemoradiation for anal cancer patients. To estimate the relevance of inguinal recurrence, we compared the incidental dose to the AILD in anal cancer (AC) patients who were treated either with Volumetric Arc Therapy – Intensity Modulated Radiation Therapy (VMAT-IMRT) or conventional 3D-radiation technique.

Methods: One VMAT-IMRT-plans and one 3D-plans were calculated on the same target volumes and identical dose prescription in ten patients. We defined the volume of the AILD on the planning CT-scans based on the information of new fluorescence methods. Furthermore, we defined several anatomical subvolumes of interest inside the AILD. We examined and compared absolute and relative dosimetric parameters of the AILD and different anatomical subunits.

Results: The Dmean of the AILD was 40 Gy in the 3D-group and 38 Gy in the IMRT-group. Dmean and Dmedian as well as the V30Gy of the AILD and all subvolumes of the caudal AILD were significant higher using 3D-RT compared to IMRT. Even though the absolute differences were small, in the caudal aspect of the ano-inguinal lymphatic drainage the V30Gy could be more than 10% less with VMAT-IMRT.

Conclusions: 3D-RT was slightly superior to IMRT in terms of dose coverage of the AILD. However, the absolute differences were very small. Some relevant caudal parts of the AILD received an insufficient dose for treating potential micrometastases. Particularly in high-risk situations, this may lead to inguinal recurrence and therefore the true deep AILD should be included into the target volume in high risk patients.

Document type: Article
Journal or Publication Title: Radiation Oncology
Volume: 13
Number: 227
Publisher: BioMed Central
Place of Publication: London
Date Deposited: 03 Dec 2018 13:55
Date: 2018
ISSN: 1748-717X
Page Range: pp. 1-7
Faculties / Institutes: Medizinische Fakultät Heidelberg > Chirurgische Universitätsklinik
DDC-classification: 610 Medical sciences Medicine
Uncontrolled Keywords: Anal Cancer, Ano-inguinal lymphatic drainage, Dosimetric quantification, IMRT
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative