Direkt zum Inhalt
  1. Publizieren |
  2. Suche |
  3. Browsen |
  4. Neuzugänge rss |
  5. Open Access |
  6. Rechtsfragen |
  7. EnglishCookie löschen - von nun an wird die Spracheinstellung Ihres Browsers verwendet.

Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis

Spranz, David M. ; Bruttel, Hendrik ; Wolf, Sebastian I. ; Zeifang, Felix ; Maier, Michael W.

In: BMC Musculoskeletal Disorders, 18 (2017), Nr. 478. S. 1-5. ISSN 1471-2474

[thumbnail of 12891_2017_Article_1835.pdf]
Vorschau
PDF, Englisch
Download (524kB) | Lizenz: Creative Commons LizenzvertragFunctional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis von Spranz, David M. ; Bruttel, Hendrik ; Wolf, Sebastian I. ; Zeifang, Felix ; Maier, Michael W. steht unter einer Creative Commons Namensnennung 4.0

Zitieren von Dokumenten: Bitte verwenden Sie für Zitate nicht die URL in der Adresszeile Ihres Webbrowsers, sondern entweder die angegebene DOI, URN oder die persistente URL, deren langfristige Verfügbarkeit wir garantieren. [mehr ...]

Abstract

Background: The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS).

Methods: Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 shoulder joints. Stemless TSA was performed in 12 shoulder joints (group STEMLESS), third-generation stemmed TSA in 13 shoulder joints (group STEMMED). Functional results were documented using the CS. 3D-motion-analysis using the Heidelberg upper extremity model (HUX) was conducted to measure active maximum (ROM).

Results: The group STEMLESS achieved a CS of 67.9 (SD 12.0) points and the group STEMMED of 70.2 (SD 5.8 points) without significant difference between the groups (p = 0.925). The maximum ROM of the group STEMLESS, ascertained by 3-D-motion-analysis, was in forward flexion 125.5° (SD 17.2°), in extension 49.4° (SD 13.8°), in abduction 126.2° (SD 28.5°) and in external rotation 40.3° (SD 13.9°). The maximum ROM of the group STEMMED, also ascertained by 3-D-motion analysis, was in forward flexion 135.0° (SD 16.8°), in extension 47.2° (SD 11.5°), in abduction 136.3° (SD 24.2°) and in external rotation 40.1° (SD 12.2°). The maximum ROM of the STEMLESS group was lower in forward flexion and abduction, higher in extension and almost identical in external rotation. But there was no significant difference (forward flexion p = 0.174, extension p = 0.470, abduction p = 0.345, external rotation p = 0.978).

Conclusion: Both types of shoulder prostheses achieve a similar and good active ROM and similar results in CS.

Trial registration: DRKS00013166, retrospectively registered, 11.10.2017

Dokumententyp: Artikel
Titel der Zeitschrift: BMC Musculoskeletal Disorders
Band: 18
Nummer: 478
Verlag: BioMed Central
Ort der Veröffentlichung: London
Erstellungsdatum: 24 Apr. 2018 09:57
Erscheinungsjahr: 2017
ISSN: 1471-2474
Seitenbereich: S. 1-5
Institute/Einrichtungen: Medizinische Fakultät Heidelberg und Uniklinikum > Orthopädische Klinik
DDC-Sachgruppe: 610 Medizin
Leitlinien | Häufige Fragen | Kontakt | Impressum |
OA-LogoDINI-Zertifikat 2013Logo der Open-Archives-Initiative