Directly to content
  1. Publishing |
  2. Search |
  3. Browse |
  4. Recent items rss |
  5. Open Access |
  6. Jur. Issues |
  7. DeutschClear Cookie - decide language by browser settings

Scintillation Light Detection and Application of Silicon Photomultipliers in Imaging Calorimetry and Positron Emission Tomography

Tadday, Klaus Alexander

German Title: Nachweis von Szintillationslicht und Anwendung von Silizium Photomultipliern in der Bildgebenden Kalorimetrie und in der Positronen-Emissions-Tomographie

[thumbnail of Dissertation_Alexander_Tadday.pdf]
Preview
PDF, English
Download (20MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Diese Arbeit befasst sich mit den schwachen Lichtsignalen von organischen und anorganischen Szintillatoren und deren Nachweis mit Silizium Photomultipliern (SiPM). In diesem Zusammenhang werden zwei Anwendungsgebiete untersucht: Hadronkalorimeter und das bildgebende Verfahren der Positronen-Emissions-Tomographie. Das Ergebnis einer Messung des Birksschen Koeffizienten kB wird vorgestellt für die Plastikszintillatorkacheln des analogen hadronischen Kalorimeterprototyps der CALICE Kollaboration. Der ermittelte kB-Wert ist signifikant größer als der bisher in Geant4-Simulationsstudien benutzte Wert. Eine neue Simulationsmethode wurde entwickelt, mit deren Hilfe eine verbesserte Beschreibung des Ionisations-Quenching-Effekts möglich ist. Der Einfluss auf das simulierte Kalorimetersignal wird anhand einer Teilchenschauer-Simulationsstudie verdeutlicht. Eine Testumgebung wurde entwickelt um eine vollständige SiPM Charakterisierung zu ermöglichen und verschiedene SiPM Bauarten zu vergleichen. Das Messspektrum umfasst die Bestimmung der Photon-Detektions-Effizienz unter Berücksichtigung der Beiträge des optischen Übersprechens und der auftretenden Nachpulse. Zusätzlich wurde das räumliche Ansprechverhalten einzelner Pixel gemessen. Die gewonnenen Erkenntnisse zu den unterschiedlichen Sensortypen und die daraus abgeleitete Qualifikation für verschiedene Anwendungsgebiete werden diskutiert. Um die Eignung von SiPMs für die Positronen-Emissions-Tomographie zu untersuchen, wurde ein Detektorprototyp im kleinen Maßstab entwickelt. Erste Charakterisierungsstudien des Systems werden vorgestellt.

Translation of abstract (English)

This thesis deals with the weak light signals created in organic and inorganic scintillators, and their detection with silicon photomultipliers (SiPM). In this context, two fields of application are studied: hadron calorimetry, and the medical imaging technique of positron emission tomography. The result of a measurement of Birks’ coefficient kB is presented for the plastic scintillator tiles used in the analogue hadronic calorimeter prototype of the CALICE collaboration. The extracted kB is significantly larger compared to the default value used in previous Geant4 simulation studies. A new simulation method was developed which enables an improved description of the ionisation quenching effect. The impact on the simulated calorimeter response is demonstrated by means of a particle shower simulation study. A test environment was developed in order to pursue a complete SiPM characterisation, thus enabling a comparison of different SiPM types. The range of measurements covers the determination of the cross-talk and after-pulse corrected photon detection efficiency, and measurements of the spatial uniformity of single pixels. The characteristics of several different SiPM types and the derived qualification for different fields of application are discussed. In order to investigate the utility of SiPMs for the positron emission tomography application, a small-scale detector prototype was developed. First characterisation studies on the system are presented.

Document type: Dissertation
Supervisor: Schultz-Coulon, Prof. Dr. Hans-Christian
Date of thesis defense: 14 December 2011
Date Deposited: 16 Jan 2012 15:07
Date: 2011
Faculties / Institutes: The Faculty of Physics and Astronomy > Kirchhoff Institute for Physics
DDC-classification: 530 Physics
Controlled Keywords: Hadronkalorimeter, Positronen-Emissions-Tomographie, Photodetektor, Szintillator
Uncontrolled Keywords: Silizium Photomultiplier , Bildgebendes KalorimeterSilicon Photomultiplier , Imaging Calorimetry , Positron Emission Tomography
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative