Entwicklung einer Ersatztechnologie für den Standard 3-He Detektor zum Nachweis thermischer Neutronen auf großen Flächen

Modzel, Gerd

English Title: Development of a replacement technology for the standard 3-He detector for the detection of thermal neutron on large areas

[thumbnail of Doktorarbeit_gedruckt_07.06.2014.pdf]
Preview
PDF, German - main document
Download (23MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Das Konzept des großflächigen Jalousie Detektors als Ersatz für 3-He basierte Neutronendetektoren wurde entwickelt und Prototypen nach den Anforderungen des POWTEX Diffraktometers entwickelt und gebaut. Der Detektor basiert auf geneigten, gestaffelten, mit 10-B beschichteten Flächen, die Neutronen absorbieren und dessen Konversionsprodukte in einem Gasdetektor nachgewiesen werden. Die Ortsauflösung wurde mit FWHM-z=11,9mm und FWHM-theta=6,4mm gemessen. Die Effizienz der korrelierten Kathoden und Anoden folgt der erwarteten Winkelabhängigkeit. Die absolute Effizienz der Anodendrähte wurde bei 1,17Å gemessen und entspricht 93,6% des vorhergesagten Wertes und validiert somit das Konzept.

Zum besseren Verständnis des Detektors wurden Simulationen in Garfield durchgeführt. Werkzeuge zur Analyse der Rohdaten des Detektors wurden entwickelt, die es ermöglichten, die Datenverarbeitung zu optimieren und die Ursachen von Problemen zu finden. Es wurde eine Testumgebung für den n-XYTER 2.0 Chip aufgebaut und erste Tests durchgeführt, die aber noch keine finale Aussage über den Chip zulassen.

Translation of abstract (English)

The large area Jalousie detector concept has been developed as a replacement for 3-He based neutron detectors. It is based on inclined and stacked layers coated with 10-B, detecting the conversion products in a gas detector. Prototypes have been built based on the requirements of the POWTEX experiment. The spatial resolution has been measured as FWHM-z=11,9mm and FWHM-theta=6,4 mm, slightly above the prediction due to the range of the conversion products in the gas. The correlated anode and cathode deliver an efficiency with the expected dependency on the inclination angle. The absolute efficiency of the anode wires has been measured as 93.6% of the predicted value at 1.17Å, validating the detector concept. Simulations in Garfield have been made to better understand the inner workings of the detector.

Tools to analyze the raw detector data have been developed, which enabled further optimizations in the data processing chain and solving some problems. A test environment has been built for the n-XYTER 2.0 chip and some preliminary tests have been conducted. They showcase some problems, but a statement about the state of the chip cannot be made yet.

Document type: Dissertation
Supervisor: Schmidt, Priv. Doz. Dr. Ulrich
Date of thesis defense: 23 July 2014
Date Deposited: 04 Aug 2014 10:05
Date: 2014
Faculties / Institutes: The Faculty of Physics and Astronomy > Institute of Physics
DDC-classification: 530 Physics
Controlled Keywords: Thermisches Neutron, Detektor, Bor-10