Ein System zur Online-Qualitätssicherung in der Strahlentherapie

Hofmann, Rüdiger

English Title: A system for online quality assurance in radiation therapy

[thumbnail of RHofmann.pdf]
Preview
PDF, German
Download (4MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

In dieser Arbeit wird ein neuartiges System zur Kontrolle der Lamellenpositionen in einem Multi-Leaf-Kollimator (ModuLeaf MLC, MRC Systems, Heidelberg) für die intensitätsmodulierte Strahlentherapie (IMRT) vorgestellt. Eine in 400 Kanäle segmentierte flüssigkeitsgefüllte Ionisationskammer erreicht eine Ortsauflösung besser als 1 mm, bezogen auf das Isozentrum, in der Bewegungsrichtung der Lamellen, mit der die Form der Kollimatoröffnung in Echtzeít kontrolliert werden kann. Die Ionisationskammer wurde in Zusammenarbeit mit dem Forschungszentrum Karlsruhe (FZK) entwickelt und gebaut. Weitere Untersuchungen wurden angestellt, um eine geeignete Flüssigkeit als sensitives Medium der Ionisationskammer zu finden. Eine geeignete Elektronik, mit der die Kammersignale (wenige nA) gemessen werden können und eine passende Datenauslese wurden zusammengestellt. Das Potential des Systems zur Verbesserung der Qualitätssicherung in der IMRT wird diskutiert.

Translation of abstract (English)

This thesis introduces a new technique to verify the leaf position of multi leaf collimators (ModuLeaf MLC, MRC Systems, Heidelberg) for intensity modulated radiation therapy (IMRT) during beam delivery. The system is based on a liquid filled ionisation chamber which is segmentated into 400 channels. The device is able to resolve a spatial resolution better than 1 mm (at isocentre, in the direction of the leaf travel). It is possible to check the leaf position in realtime using this system. The chamber was constructed and built in cooperation with the research center in Karlsruhe (FZK). Further investigations aim to find a liquid as a sensitive medium for the ionisation chamber. A suitable set of electronics to measure the signals of the chamber (currents of a few nA) and to read out the data was arranged. The potential for improvement of the quality assurance in IMRT of the new device is discussed.

Document type: Dissertation
Supervisor: Hartmann, Prof. Dr. Günther H.
Date of thesis defense: 28 May 2003
Date Deposited: 04 Jun 2003 13:53
Date: 2003
Faculties / Institutes: Service facilities > German Cancer Research Center (DKFZ)
DDC-classification: 530 Physics
Controlled Keywords: Qualitätssicherung, Qualitätssicherungssystem, Strahlentherapie, Ionisationskammer
Uncontrolled Keywords: segmentierter Detektor , Vielkanal-Elektrometer , IMRTsegmentated detector , multi-channel electrometer , IMRT