A Monte Carlo study of the accuracy of CT-numbers for range calculations in carbon ion therapy

Qamhiyeh, Sima

[thumbnail of Qamhiyeh_PhD_thesis.pdf]
Preview
PDF, English
Download (3MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Kohlenstoffionen deponieren den größten Teil ihrer Energie in einer schmalen Region nahe der maximalen Reichweite (Bragg Peak). Die Reichweite der Ionen in Gewebe ist abhängig von der Elektronendichte des Gewebes. Diese Elektronendichte kann gegenwärtig nur mit Hilfe eines Röntgen-Computertomographen (CT) mit ausreichend räumlicher Auflösung gemessen werden. Daher ist es notwendig, möglichst exakte CT-Daten zu erhalten. Diese CT-Daten sind allerdings abhängig von den Parametern die während der Datenerfassung verwendet werden. In dieser Arbeit wird der Einfluss dieser Messparameter auf die CT-Daten mit Hilfe von Monte-Carlo Simulationen einzelner CT-Projektionen und der Rekonstruktion dieser Projektionen systematisch studiert. Abweichungen der CT-Daten aufgrund des Phantomdurchmessers sowie der Zusammensetzung des Substitutmaterials, dem verwendeten Phantommaterial und der gewählten Spannung der CT-Röntgenröhre werden untersucht. Desweiteren wird die Übertragung von Unsicherheiten in den CT-Daten in eine herapeutisch relevantere Reichweiten- und Dosisunsicherheit bei der Anwendung von Kohlenstoffstrahlen diskutiert.

Translation of abstract (English)

Carbon ions deposit most of their energy in a narrow region near the end of their range (Bragg peak). The range of ions in tissue depends on the electron density of the tissue, which can only be measured with reasonable spatial resolution using X-ray computed tomography (CT).Therefore, it is important to have accurate CT-data. However, the value of CT-numbers depends on the parameters used during the acquisition of CT-numbers. In this work, the effect of measuring conditions on CT-numbers is systematically studied by performing Monte Carlo simulations of a CT scanner and reconstructing the simulated projections. Deviations of CTnumbers due to the material of the substitutes, the material of the phantom which is used for CT measurements, the diameter of the phantom and the voltage settings of the X-ray tube are investigated. The translation of the deviations in CT-numbers into range and dose uncertainties of Carbon ions is also discussed.

Document type: Dissertation
Supervisor: Jäkel, Oliver
Date of thesis defense: 16 May 2007
Date Deposited: 23 May 2007 15:52
Date: 2007
Faculties / Institutes: The Faculty of Physics and Astronomy > Dekanat der Fakultät für Physik und Astronomie
DDC-classification: 530 Physics
Controlled Keywords: Monte Carlo
Uncontrolled Keywords: CT-numbersCarbon ion therapy