Direkt zum Inhalt
  1. Publizieren |
  2. Suche |
  3. Browsen |
  4. Neuzugänge rss |
  5. Open Access |
  6. Rechtsfragen |
  7. EnglishCookie löschen - von nun an wird die Spracheinstellung Ihres Browsers verwendet.

A new ion beam cooler and buncher for ISOLTRAP and mass measurements of radioactive argon isotopes

Herfurth, Frank

Deutsche Übersetzung des Titels: Ein neuer Ionenstrahlkühler und -pulser für ISOLTRAP und Massenmessungen an radioaktiven Argonisotopen

[thumbnail of Alles.pdf]
Vorschau
PDF, Englisch
Download (1MB) | Nutzungsbedingungen

Zitieren von Dokumenten: Bitte verwenden Sie für Zitate nicht die URL in der Adresszeile Ihres Webbrowsers, sondern entweder die angegebene DOI, URN oder die persistente URL, deren langfristige Verfügbarkeit wir garantieren. [mehr ...]

Abstract

A new ion beam cooler and buncher for ISOLTRAP and mass measurements of radioactive argon isotopes - ISOLTRAP is a Penning trap mass spectrometer installed at ISOLDE/CERN. It is set up to measure the mass of short-lived nuclides with a relative accuracy delta m / m of typically 1* 10^-7. In this work an ion beam cooler and buncher based on a linear radio frequency quadrupole trap has been installed and characterized. By this the overall efficiency of the ISOLTRAP spectrometer was increased by three orders of magnitude. This allows for measuring nuclides that are only produced in minute quantities as for instance 33Ar. In this work the mass of 33,34,42,43Ar has been measured with a relative accuracy of about 1* 10^-7. 33Ar with its half-live of only 174 ms is the shortest-lived nuclide ever investigated in a Penning trap. The high accuracy of the mass measurement of 33Ar made a stringent IMME test for the A=33, T=3/2 isospin quartets possible.

Übersetzung des Abstracts (Englisch)

A new ion beam cooler and buncher for ISOLTRAP and mass measurements of radioactive argon isotopes - ISOLTRAP is a Penning trap mass spectrometer installed at ISOLDE/CERN. It is set up to measure the mass of short-lived nuclides with a relative accuracy delta m / m of typically 1* 10^-7. In this work an ion beam cooler and buncher based on a linear radio frequency quadrupole trap has been installed and characterized. By this the overall efficiency of the ISOLTRAP spectrometer was increased by three orders of magnitude. This allows for measuring nuclides that are only produced in minute quantities as for instance 33Ar. In this work the mass of 33,34,42,43Ar has been measured with a relative accuracy of about 1* 10^-7. 33Ar with its half-live of only 174 ms is the shortest-lived nuclide ever investigated in a Penning trap. The high accuracy of the mass measurement of 33Ar made a stringent IMME test for the A=33, T=3/2 isospin quartets possible.

Dokumententyp: Dissertation
Erstgutachter: Kluge, Prof. H.-Jürgen
Tag der Prüfung: 3 Mai 2001
Erstellungsdatum: 19 Jun. 2001 00:00
Erscheinungsjahr: 2001
Institute/Einrichtungen: Fakultät für Physik und Astronomie > Physikalisches Institut
DDC-Sachgruppe: 530 Physik
Normierte Schlagwörter: Massenspektrometrie, Penning-Käfig, Strahlkühlung, Argon
Freie Schlagwörter: atomic masses , Penning trap , ion cooling , radioactive ion beam , argon