Directly to content
  1. Publishing |
  2. Search |
  3. Browse |
  4. Recent items rss |
  5. Open Access |
  6. Jur. Issues |
  7. DeutschClear Cookie - decide language by browser settings

Aufbau und Evaluierung eines taktilen Displays

Biesinger, Alexander

English Title: Construction and Evaluation of a tactile Display

[thumbnail of biesinger.pdf]
Preview
PDF, German
Download (5MB) | Terms of use

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Die Nutzung des taktilen Kanals anstelle des visuellen stellt fuer erblindete oder stark sehbehinderte Personen eine Alternative dar, mit der diese sich in ihrer Umgebung zurechtfinden koennen. Hier sollen die Grundlagen fuer ein System geschaffen werden, das dieses ermoeglicht. Dazu wird ein taktiles pneumatisch betriebenes Display erstellt. Dieses ist durch eine elektrische computergesteuerte Schaltung so regelbar, dass Versuche mit verschiedenen Reizen automatisch durchfuehrbar sind. Die Probanden die mit Hilfe des Displays taktil angeregt werden, befinden sich in einem fMRI, das Aufnahmen des Gehirns vornimmt. Diese Aufnahmen dienen dazu die gegebenen, vom Trigger des fMRI gesteureten Reize zu lokalisieren und zu quantifizieren, um die Moeglichkeiten abzuschaetzen, die ein solcher Ansatz birgt.

Translation of abstract (English)

The use of a tactile channel instead of a visual one, is an alternative help for blind or visual impaired people to find their way through the seeing world. In this work the basics are set for a system which could enable it. In order to do so, a pneumatic operating display has been built. It can be controlled by a computer tuner, so that automatic experiments, with different strength of impulses are possible. The subject lies in a fMRI and recieves the impulses, at the same time as the fMRI measures the brain activation. These scans made to locate and quantify the impulses controlled by the trigger, serve to estimate the chance in such a test.

Document type: Master's thesis
Date Deposited: 20 Mar 2000 13:55
Date: 2000
Faculties / Institutes: The Faculty of Physics and Astronomy > Kirchhoff Institute for Physics
DDC-classification: 530 Physics
Controlled Keywords: Grosshirnrinde, Taktiler Sensor, Magnetische Kernresonanz, Somatosensorisches System, Beruehrungsreiz
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative